Changes to Step #3

Edit by Christopher Howell

Edit approved by Christopher Howell

Before
After
Unchanged

Step Lines

[title] Basic Testing - Testing EVSE States
-[* black] EVSE states can be tested with a few resistors and a diode, and EV Simulator or an EVSE Tester.
+[* green] EVSE states can be tested with a few resistors and a diode, and EV Simulator or an EVSE Tester. After a sucessful Power on Self Test OpenEVSE should enter State A - Ready and the LED/LCD should be Green.
[* yellow] State B - EV Connected. Connect 2.74k resistance plus a diode from Pilot to ground. OpenEVSE display should display "EV Connected" and LED/LCD should turn Yellow.
+[* light_blue] State C - Charging. Connect 882 ohm resistance plus a diode from Pilot to ground. OpenEVSE display should display "Charging" and LED/LCD should turn Blue.
+[* red] State D - Ventilation Required. Connect 246 ohms resistance plus a diode from Pilot to ground. OpenEVSE display should display "EVSE ERROR - VENT REQUIRED" and LED/LCD should turn Red.