Changes to Step #9

Edit by Christopher Howell

Edit approved by Christopher Howell

Before
After
Unchanged

Step Lines

+[title] Advanced Testing - GFCI Lockout
+[* icon_note] OpenEVSE will lockout if a GFCI fault occurs within 2 seconds of contact closure.
+[* black] Enter State C (Charging).
+[* black] Within 2 seconds of contact closure induce GFCI Fault. OpenEVSE should display SERVICE REQUIRED - GFCI Fault.
+[* icon_caution] OpenEVSE will remain in this state until power is removed.