Changes to Step #2

Edit by Christopher Howell

Edit approved by Christopher Howell

Before
After
Unchanged

Step Lines

[title] Mounting Plate
-[* icon_caution] If your kit contains a Packard C240C contactor, continue here. [guide|8|Guide]
-[* black] Position the plate with the 4 holes for the OpenEVSE controller up top and the Earth Ground bus bar on the right.
-[* black] Mount hex standoffs to the top side of the plate with 6 mm screws.
-[* black] Mount ground bar to the plate with 2 - 5/8" self threading screws.
- [* icon_note] Note: Kits now include a 2 position ground bar.
-[* black] Mount the [https://relays.struthers-dunn.com/configurator/450-series-power-relays|Struthers-Dunn relay] using 2 - 1/2" self threading screws.
+[* black] Position the plate with the 4 holes for the OpenEVSE controller up top-left.
+[* blue] Mount hex standoffs to the top side of the plate with 6 mm screws.
+ [* icon_note] Tip - use blue LOCTITE on each screw to ensure it remains tight.
+[* red] Mount the [https://relays.struthers-dunn.com/configurator/450-series-power-relays|Struthers-Dunn relay] using 2 - 1/2" self threading screws.
+[* green] Mount ground bar to the plate with 1 - 1/4" self threading screws.

Image 1

Old Version

New Version

Image 2

Old Version

New Version

Image 3

Old Version