Crimp 22AWG wire to larger 1/4" pink QC connectors. Connect to Fuse block QC terminals.

Screw the 22AWG wires to the "AC Line - N" and "AC Line - H" block on the OpenEVSE board.

When connecting relay coil tabs. Ensure the QC terminal slides down the tab. It is possible to wedge the QC connector in by bending tab to the side.

Connect OpenEVSE common relay output (center pin) to 1 relay coil terminal on each relay using small pink QC connectors.

Connect OpenEVSE controller Relay 1 output to remaining pin on first Relay.

Connect OpenEVSE controller screw terminal Relay output 2 to remaining pin on second relay.