Step Type:

Drag to rearrange

OpenEVSE checks for Earth Ground Continuously while Charging (State C).

Testing - Connect EV Simulator. Enter State C Charging. Disconnect Earth Ground from the OpenEVSE board. OpenEVSE should enter and Error state and Display "EVSE ERROR - NO GROUND".

Restore Ground Connection. EVSE should resume charging within 1 minute.