Insert the AC Input cable through the LEFT Cable Gland and assemble loosely into the hole in the box.

Check the color code for your country and plug type as it varies region by region. Pictures show US 3 wire (Green, White, Black). Note US 4 wire (Green, White, Black, Red) White Neutral not used and should be capped.

Run the Ground wire along the bottom of the enclosure and secure the conductor the the ground block.

Screw Ring Terminals to the contactor with the Quick connect terminal for OpenEVSE AC_Line on top.

Tighten the cable gland and check its integrity. Check the input wires are secure.