Insert EV Cable through the Cable Gland on the right and tighten.

Route the ground and pilot wires low in the enclosure up the right side.

Thread ALL hot and neutral lines through the 4 wire GFCI coil with the orange self test loop.

Do not thread the ground wire or pilot wire through.

Thread only ONE hot line through the Current Measurement Coil.