Insert EV Cable through the Cable Gland on the right and tighten.

Connect the ground wire to the ground block.

Route the ground, pilot and coil wires low in the enclosure to avoid crossing any high voltage wires or components.

Thread ALL hot and neutral lines through the 4 wire GFCI coil with the orange self test loop.

Do not thread the ground wire or pilot wire through.

Advanced Series Only - Thread EITHER hot OR neutral through the Current Measurement Coil.

Tip - zip tie smaller wires together near the top and bottom to keep them neat and out of the way.