Editing Step 6 —

Step Type:

Drag to rearrange

Insert the input cable through the left gland.

Connect the ground wire to the ground block.

Screw the ring terminal on the EV cable power conductor to the top position of relay along with the red wire on the wiring harness.

Ensure both Input cable ring terminals have good contact directly to the relay pads and the screw is tight.

Install the harness wires on top of the EV cable connector to insure the EV cable has the best contact with the relay as possible.

Screw the ring terminal on the EV cable power conductor to the bottom position of relay along with the black wire on the wiring harness.

Tip - run the top power wire in low in the enclosure.

Tip - run the bottom power wire high in the enclosure and angled away from the top power wire. Ensure there is plenty of clearance.