Skip to main content
Help

Site Navigation

Your Account

Choose Language

Editing Step 5 —

Step Type:

Drag to rearrange

Remove insulation from the GREEN and BLACK wire.

Insert the ground pin on the 10AWG GREEN wire and the 18AWG BLACK Proximity wire.

Note the Ground pin is different from the power pins. Note the notch near the area where the wire is inserted.

Crimp Ground pin with Pico Corporation 400B pneumatic crimping tool at 80PSI.

Recommended Die Pico 414DA-8N

Recommended locator - OpenEVSE J1772 Power/Ground

Soldering the pins is possible but requires a lot of heat to get solder to flow throughout. Crimping is recommended.

Your contributions are licensed under the open source Creative Commons license.